1-877-804-9940
1-877-804-9940
XPOWER commercial dehumidifiers from 60 to 165 pints per day at AHAM conditions, built for structural drying after a water loss. Low grain refrigerant models pull moisture at lower humidity levels than conventional refrigerant units, which is what shortens the back end of a dry. Every unit carries an automatic purge pump or continuous drainage, so nobody returns to site to empty a tank.
Why Shop With FacilitySupplyPro?
Which Dehumidifier Is Right for You?
Two decisions: capacity against the size of the loss, and whether you need LGR performance or a conventional refrigerant unit will do.
| Model | At AHAM | At Saturation | Type | Best For |
|---|---|---|---|---|
| BD-65 | 60 PPD | 120 PPD | Conventional, R32 | Smaller spaces, stainless housing, 55.1 lbs |
| XD-125 | 76 PPD | 125 PPD | Conventional | General purpose, semi pneumatic tires for rough sites |
| BD-90P | 85 PPD | 195 PPD | Conventional, R32 | Sustained commercial duty, stainless housing |
| XD-85L2 | 85 PPD | 145 PPD | LGR | Crawl spaces and tight areas, 70.5 lbs |
| XD-90L | 85 PPD | 145 PPD | LGR, R32 | Updated XD-85L2, round port for lay flat ducting |
| CD-90L | 85 PPD | 195 PPD | LGR, R32 | Higher saturation output in the 85 PPD class |
| XD-130Li | 125 PPD | 220 PPD | LGR | Bluetooth monitoring without opening containment |
| XD-165L | 165 PPD | 280 PPD | LGR | Large loss work where drying time drives job cost |
LGR or conventional? A conventional refrigerant dehumidifier works efficiently while the air is still humid, then loses effectiveness as relative humidity drops. An LGR unit pre-cools incoming air so it keeps pulling moisture at low grain depths, which is exactly where a conventional unit stalls. For general humidity control, conventional is fine and cheaper. For restoration where you are drying to a standard and billing by the day, LGR pays for itself in fewer days on site.
Read the two capacity ratings correctly. AHAM is measured at 80 degrees Fahrenheit and 60 percent relative humidity, close to real working conditions. The saturation figure is measured at 90 and 90, and you will only see it in the first hours of a fresh loss. Size from the AHAM rating.
Related
Tell us the affected square footage, the class of water loss, and how many days you have, and we will size it. Email info@facilitysupplypro.com or call 1-877-804-9940.
Application LeadThe XPOWER XD-125 is a commercial dehumidifier removing 76 pints per day at AHAM conditions and 125 pints per day at 90 degrees and...
View full detailsApplication LeadThe XPOWER XD-90L is the R32 refrigerant update to the XD-85L2, removing 85 pints per day at AHAM and 145 pints per day at saturati...
View full detailsApplication LeadThe XPOWER XD-85L2 is a commercial LGR dehumidifier removing 85 pints per day at AHAM and 145 pints per day at saturation. At 70.5 ...
View full detailsApplication LeadThe XPOWER XD-165L is a high capacity LGR dehumidifier removing 165 pints per day at AHAM and 280 pints per day at saturation, with...
View full detailsApplication LeadThe XPOWER XD-130Li is a commercial LGR dehumidifier rated at 125 pints per day at AHAM and 220 pints per day at saturation, moving...
View full detailsApplication LeadThe XPOWER Viking CD-90L is a commercial LGR dehumidifier removing 85 pints per day at AHAM and 195 pints per day at saturation. Lo...
View full detailsApplication LeadThe XPOWER Viking BD-90P is a commercial dehumidifier rated at 85 pints per day at AHAM and 195 pints per day at full saturation, m...
View full detailsApplication LeadThe XPOWER Viking BD-65 is a commercial dehumidifier removing 60 pints per day at AHAM conditions and up to 120 pints per day at fu...
View full details$50.00 away from free shipping!
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}